  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
  • High-Efficiency 90kw Direct Current Motor for Industrial Applications
Find Similar Products

Basic Info.

Model NO.
LTY-Motor-001
Power Rating
90kw
Casing Protection
Protection Type
Number of Poles
12
Speed
High Speed
Type
Zsn
Operating Speed
Constant Speed
Function
Control
Structure and Working Principle
Brush
Brand
Shengling
Transport Package
Wooden Case
Specification
Z4-200-31
Trademark
shengling
Origin
China
Production Capacity
100sets/Month

Product Description

Z series DC motor used polygon structure so that the using rate of the stators inner space is very high. The magnet yoke is laminated style, suitable for silicon controlled commutate power supply and it can endure pulsating current and rapid change of current (load change).Magnetic poles are fixed by precise orientation. All the motors of system are with compensate winding, so the reverse performance is very well.
The insulation class of the motor is F, using of reliable insulation structure and nonmenstruum vacuum pressure impregnated, guaranteeing the stable performance of insulation and good heat dissipation.
 
perfomance
 
1. The standard rated voltage of the electromotor are 440V, 550V, 660V, 750V etc. Voltage of other classes can also be derived according specific situation, but must be negotiated when ordering.

2. The basic excitation style is separately excited, the excited voltage is 220V, Voltage of other classes can also be derived according specific situation, but must be negotiated when ordering.

3. Short time overload capacity of motor.
Motor can be divided into two kinds according to the use
First kind (A): ordinary industrial DC motor; Second kind (B): metal rolling mill DC motor.
a) First kind (A) motor can endure the overload (1min) according to table 1
Table 1
percentage of basic speed
percentage of basic speed
seldom using
constantly using
100
200
175
200
160
150
>300
140
125

b) First kind (B) motor can endure the overload (1min) according to table 2
Table 2
percentage of basic speed
percentage of basic speed
seldom using
constantly using
100
200180*
175160*
200
160180*
160
>300
175160*
140
*When the basic speed of the motor≥650r/min,using the number in the bracket.

c) The short time overload capacity seldom used means happens infrequency or only at the urgency, the motor working exceed the continuous rated overload capacity, we suggest you adjust the instantaneous open/close device of the switch according to the short time overload capacity seldom using.
The short time overload capacity seldom constantly used means its an part of the normal working period, the motor endure the continuous rated overload capacity again and again. After working at short time overload, it must working light load to make the overload periods overload root-mean-square less than its continuous ration.
 
d) Second kind DC motor(B)can endure the following continuous load; Working continuous within the rated voltage and rotate speed with 115% rated power overload, the temperature is higher when at this overload, other features maybe different from working at the rated condition.
Within the rated voltage and rotate speed, after running at the rated overload, working at the 125% rated power for two hours, the temperature rise cant overrun the regulated numerical value other features maybe different from working at the rated condition.

e) Second kind DC motor(B),at the rated rotate speed, the overload can reach 2.5 times no longer than 15s only used once in a while.

4. The change rate of current
    Under all rotate speed and load, the change rate of current (di/dt) that   the motor can endure is 250 times rated current.
 
5. Libration and noise
a) the libration of the motor accords with GB10068Measurement evaluation and limits of the vibration severity of rotating electrical machines which the shaft center height is 56mm and above center standards regulation.
b) The noise of the motor accords with GB10069.3 Measurement of airborne noise emitted by rotating electrical machinery and noise limits.
6.working condition
a) Altitude above sea level maximal is1,000m;
b) Cooling air temperature maximal is 40oC; Cooling water temperature   maximal is 32oC;
c) The motor can be installed under foul situation, but the right cooling   method of cooling method of cooling and defend class must be chosen. If the situation is special, please negotiate.
d) The motor is suitable for 3-phase bridge rectfier power supply, also can adopt power supply of DC generator.
e) The motor accord with GB755 ''The ration and performance of the   rotating electrical machinery'', IEC60034-1 ''The ration   
and performance of the rotating electrical machinery'' and JB/T9577 ''Technical requirements of Z series middle motor electromotor''.
7.The efficiencies listed in the data sheet are for rated output, voltage and speed, and include excitation loss.

The choice of the motors capacity
    1.First kind (A): Ordinary industrial DC motor. The technical data of this kind of motor please see the technical data table. The buyer can decide the capacity, voltage, running speed and the method of cooling of the motor at the buyers option.
    2. Second kind (B): Metal rolling mill DC motor. The output power of this kind of motor is about 20% lower than kind (A), the detail numerical value can be negotiated by the user and the manufacture.
    3. Exclude the specification of technical data in the table. Manufacturer can derive other specification at the requirement of the user.
High-Efficiency 90kw Direct Current Motor for Industrial ApplicationsHigh-Efficiency 90kw Direct Current Motor for Industrial ApplicationsHigh-Efficiency 90kw Direct Current Motor for Industrial ApplicationsHigh-Efficiency 90kw Direct Current Motor for Industrial ApplicationsHigh-Efficiency 90kw Direct Current Motor for Industrial Applications